* RECOMMENDED * HPE Offline Bundle for ESXi 6.7 By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. | Type: | Software - System Management | | Version: | 3.4.5(16 Sep 2019) | | Operating System(s): | VMware vSphere 6.7 | | File name: | esxi6.7uX-mgmt-bundle-3.4.5-8.zip (30 MB) |
HPE ESXi Offline Bundle for VMware ESXi 6.7. The HPE ESXi Offline Bundle for VMware ESXi 6.7 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. Agentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: | 597213157d03f3248faeba84c7800a805bde6bebb6e757493d0e1d76a03f4afd | esxi6.7uX-mgmt-bundle-3.4.5-8.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.7 Host Using vSphere CLI 6.7 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch an vSphere 6.7 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.7 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.7, see the VMware vSphere Command-Line Interface Installation and Reference Guide. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml> - Install remotely from client, with offline bundle on ESXi host:
esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip> - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d <ESXi local path><bundle.zip>
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
esxcli -s <server> -u root -p mypassword software vib list - (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.7 Host Using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. End User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
This tutorial doesn't include how to unpack NSP, XCI or NCA. It's for people who already knows that. Recompile exe file. F.e.This package doesn't work with encrypted files, but Switch for most games (if not all) has decrypted archives for sake of better performance.This tutorial is made purposely for mount point./././ which is default for Switch games. Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/ Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts every 5 minutes
Version:3.5.0 (17 Jan 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
- Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service - Fix buffer overrun when acquiring vib summary from ESXi host database
- Fix cpqSePciSlotBoardName for empty slots with no CPU
- Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
- Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
- Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts every 5 minutes
Agentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
- Fixed XML parser issues affecting online Firmware Update
Agentless Management Service - Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service - Added support for cpqiscsi MIB
- Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
- Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.5 (2 Oct 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed the data size returned for the ipAddrTable MIB IPaddress which causes some SNMP Client Software such as HPE SIM to fail ESXi host discovery.
Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service - Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
- Fixed memory leak partly caused by AMS running in the OS init resource group
- Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers - Added support for Smart Array Controller model P408i-sb
Agentless Management Service - Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (20 Apr 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service features: - Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
- Added support for reporting multiple IPV6 addresses configured for Ethernet ports
- Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
- Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
WBEM Provider features: - Added support for the new Fibre Channel(FC) HBA
| Type: | Software - System Management | | Version: | 3.4.5(16 Sep 2019) | | Operating System(s): | |
DescriptionHPE ESXi Offline Bundle for VMware ESXi 6.7. The HPE ESXi Offline Bundle for VMware ESXi 6.7 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. EnhancementsAgentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Installation InstructionsTo ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: | 597213157d03f3248faeba84c7800a805bde6bebb6e757493d0e1d76a03f4afd | esxi6.7uX-mgmt-bundle-3.4.5-8.zip |
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained. Installation:
Installing Offline Bundles on an vSphere 6.7 Host Using vSphere CLI 6.7 esxcli Utility You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles. Prerequisites Before you can update or patch an vSphere 6.7 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.7 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.7, see the VMware vSphere Command-Line Interface Installation and Reference Guide. Procedure - Power off any virtual machines that are running on the host and place the host into maintenance mode.
- Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
- Install the bundle on the ESXi host.
- Install remotely from client, with offline bundle contents on a online depot:
esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml> - Install remotely from client, with offline bundle on ESXi host:
esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip> - Install from ESXi host, with offline bundle on ESXi host:
esxcli software vib install -d <ESXi local path><bundle.zip>
- After the bundle is installed, reboot the ESXi host for the updates to take effect.
- (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
esxcli -s <server> -u root -p mypassword software vib list - (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.7 Host Using VMware vCenter Update Manager The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide. Release NotesEnd User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/ FixesUpgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts every 5 minutes
Revision HistoryVersion:3.5.0 (17 Jan 2020) Steinberg halion 3 crackheads. Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
- Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service - Fix buffer overrun when acquiring vib summary from ESXi host database
- Fix cpqSePciSlotBoardName for empty slots with no CPU
- Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
- Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
- Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
- Fixed issue with read spikes seen in Gen9 hosts every 5 minutes
Agentless Management Service - Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
- Fixed XML parser issues affecting online Firmware Update
Agentless Management Service - Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service - Added support for cpqiscsi MIB
- Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
- Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.5 (2 Oct 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service - Fixed the data size returned for the ipAddrTable MIB IPaddress which causes some SNMP Client Software such as HPE SIM to fail ESXi host discovery.
Version:3.3.0 (27 Jun 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. WBEM Providers - Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service - Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
- Fixed memory leak partly caused by AMS running in the OS init resource group
- Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers - Added support for Smart Array Controller model P408i-sb
Agentless Management Service - Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (20 Apr 2018) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Agentless Management Service features: - Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
- Added support for reporting multiple IPV6 addresses configured for Ethernet ports
- Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
- Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
WBEM Provider features: - Added support for the new Fibre Channel(FC) HBA
|
|